Atomic Absorption Spectrophotometer

Model : SP-AA4530

Wavelength Range : 190-900nm
Accuracy of the Wavelength : ±0.15nm
Receptivity of the Wavelength : ≤0.04nm
Size(W×D×H)(mm) : 730×625×700
Availability:
Quantity:

Atomic Absorption Spectrophotometer Specifications:

ModelSP-AA4530
Wavelength Range190-900nm
Spectral Bandwidth0.1/0.2/0.4/1.0/2.0 nm
Accuracy of the Wavelength±0.15nm
Receptivity of the Wavelength≤0.04nm
Base Line Stability≤0.002A/30min (Cu)
Characteristic Viscosity0.02μg/ml/1% (Cu)
Checking Limit0.004μg/ml (Cu)
Preciseness0.005
Grating1800 lines/mm
InflamerAll-metal titanium burner
AtomizerEffective glass atomizer
Lamp Stand8
D2 Background Correction Ability

When the background is 1A, the background ability should be deducted not less than 50 times, self absorption background deduction method

Power Source220V±22V AC
Shipping Size(W×D×H)(mm)860×705×755(Main instrument)
1170×645×900(Accessories)
G.W. (kg)105 (Main instrument); 100 (Accessories)
Flame System
Acetylene Air Burner100mm
Lgnition Dynamic Baseline Drift≤0.006A/30min
(Cu) Characteristic Viscosity≤0.025μg/ml/1%
Related Standard Deviation of the Accuracy≤0.5% (Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety System

Can automatically cut off the gas when the pressure is not enough the power is off flame out and unconformity of the burner

Graphite Furnace
The Highest Temperature3000℃
The Largest Temperature Rising Speed≥2000℃/s
Characteristic QuantityCd≤0.5×10-12g Cu≤0.5×10-11g
AccuracyCu≤3% Cd≤3%
Size (mm) and Weight730×625×700; 79.3kg
Safety SystemOver current protection
Low air pressure alarm/protection
Low cooling water flow alarm/protection
Power Source and Power220V±22V AC 7000W

Atomic Absorption Spectrophotometer Features:

The atomic absorption spectrophotometer is PC-controlled and uses advanced graphite furnace temperature control technology. Its unique optical and mechanical design and various convenient features make it ideal for various industries. Here are some of its features:


1. Complete automatic control system, fully PC controlled. You can quickly realize:

  • Automatic ignition and extinguishing

  • Graphite furnace test method setting wavelength scanning and peak seeking determination

  • Selection of atomizer

  • Gas flow control

  • Advanced graphite furnace temperature control technology

  • The setting of the background deduction method

  • Elevator up and down front and back adjustment

  • Adjustment of light energy

2. Integrated floated optical platform design can improve the visual system shock resistance and keep it stable though using the optical signal for a long time.

3. The flame burner can automatically adjust the optimum height

4. Simultaneous preheating of eight lamps with automatic change of selection

5. Fully automatic peak search and wavelength scanning

6. Full range of safety features, including flame anomalies, gas leaks, under-pressure alarms and automatic safety protection.

7. Self-absorbing background and deuterium lamp adjustment

8. Superior data processing capability


Advanced Graphite Furnace Temperature Controlling Technology

1. PID technology ensures more accurate temperature control even with voltage fluctuations and resistance changes.

2. Fast sampling techniques are used to obtain reliable test data

3. The furnace has a fast heat-up capability for increased component flexibility

4. It can be powered by a 220V power supply with a maximum heating capacity set to 20 levels for testing different samples

5. Can adjust the gas flow  to three different levels to suit a variety of applications

6. The Atomic absorption spectrophotometer has an alarm system that alerts the user during a low gas or water supply.


Safe and reliable flame system

1. EPC for more precise control of acetylene (C2H2) flow and easier handling

2. Highly efficient atomization system for higher sensitivity

3. High safety with automatic alarms for flame anomalies, power failures, insufficient pressure, etc.

4. Automatic gas shut-off in case of abnormality


Multifunctional Software Workstation

Supports WINDOWS7

1. Rich menus make operation more convenient

2. Convenient conversion between different menus makes the process easier.

3. Multiple analysis and correction methods provide users with more choices.

4. Supports flexible storage and editing


Previous: 
Next: 
Get Quotation/Become Distributor

About Company​​​​​​​

As a professional lab and medical equipment manufacturer, Scitek Global is certified by ISO 9001, ISO 13485, ISO 45001 and ISO 14001. Almost all our products are certified by ETL, CE and FDA .

Scitek Global looks forward to establishing cooperation with more distributors all over the world, and working together to create greater customer value.

Quick Links

Contact Us
Scitek Global Co.,Ltd
  No. 7000 Jingshi Road, Jinan City, Shandong Province, China
/  +86-531-82893797
  Inquiry: info@scitekglobal.com
Service: 
service@scitekglobal.com
Complaints: 

complaints@scitekglobal.com
 
Scitek Global Inc.
9999 Bellaire Blvd Ste 505, Houston, TX 77036, United States
  +1 (915) 4126735
info@scitekglobal.net
 
Scitek Ethiopia
 tsion@scitekglobal.com
Copyright © 2023 Scitek Global Co., Ltd. All rights reserved.  Sitemap  Privacy Policy