Availability: | |
---|---|
Quantity: | |
Model | DT-I | DT-III | DT-VI | DT-DVI | DT-DVIII | DT-VIII | DT-DSVIII |
---|---|---|---|---|---|---|---|
Speed Range | 20~200rpm | 20~250rpm | |||||
Speed Accuracy | ±2rpm | ±1rpm | ±2rpm | ||||
Temperature Range | Ambient temperature~+45.0℃ | ||||||
Temperature Stability | ±0.3℃ | ||||||
Preset Timing Nine Points | 5~900 min | 1~999 min | |||||
Time Accuracy | ±0.5min | ±0.3% | |||||
Paddle Radial Run-out | ±0.5mm | ||||||
Basket Radial Run-out | ±1.0mm | ||||||
Power Supply | AC220/110V, 50/60Hz | ||||||
Size(W×D×H)(mm) | 260x300x480 | 510x300 x480 | 960x440x480 | 960x320 x480 | 960x320 x480 | 960x440 x480 | 680x540 x480 |
Shipping Size(W×D×H)(mm) | 520x450x590 | 770x420x590 | 1240x460x570 | 1210x500x600 | 1230x650 x620 | 1230x590 x570 | 870x640 x610 |
N.W./G.W. (kg) | 15/20 | 30/35 | 44/65 | 82/90 | 86/100 | 48/80 | 60/80 |
Dissolution tester determines the rate and extent of drug dissolution in tablets, capsules and other solid preparations in a defined solvent.
Single-cup single test to ensure the independence of each test.
The head part of the machine adopts manual turning, which is a stable and flexible operation.
Core parts such as flip blue and paddle shaft are made of SUS316L stainless steel with good corrosion resistance.
Adopting a micro pump circulating water flow uniform heating system, the water bath temperature is uniform.
Full-automatic intelligent control of the measurement of time, temperature, and speed, with flexible operation to ensure the accuracy of the measurement.
Real-time display of the actual value and preset value, intuitive display of data to facilitate users to compare data
With automatic operation detection, the operation process can also automatically diagnose whether the fault and alarm function.
Model | DT-I | DT-III | DT-VI | DT-DVI | DT-DVIII | DT-VIII | DT-DSVIII |
---|---|---|---|---|---|---|---|
Speed Range | 20~200rpm | 20~250rpm | |||||
Speed Accuracy | ±2rpm | ±1rpm | ±2rpm | ||||
Temperature Range | Ambient temperature~+45.0℃ | ||||||
Temperature Stability | ±0.3℃ | ||||||
Preset Timing Nine Points | 5~900 min | 1~999 min | |||||
Time Accuracy | ±0.5min | ±0.3% | |||||
Paddle Radial Run-out | ±0.5mm | ||||||
Basket Radial Run-out | ±1.0mm | ||||||
Power Supply | AC220/110V, 50/60Hz | ||||||
Size(W×D×H)(mm) | 260x300x480 | 510x300 x480 | 960x440x480 | 960x320 x480 | 960x320 x480 | 960x440 x480 | 680x540 x480 |
Shipping Size(W×D×H)(mm) | 520x450x590 | 770x420x590 | 1240x460x570 | 1210x500x600 | 1230x650 x620 | 1230x590 x570 | 870x640 x610 |
N.W./G.W. (kg) | 15/20 | 30/35 | 44/65 | 82/90 | 86/100 | 48/80 | 60/80 |
Dissolution tester determines the rate and extent of drug dissolution in tablets, capsules and other solid preparations in a defined solvent.
Single-cup single test to ensure the independence of each test.
The head part of the machine adopts manual turning, which is a stable and flexible operation.
Core parts such as flip blue and paddle shaft are made of SUS316L stainless steel with good corrosion resistance.
Adopting a micro pump circulating water flow uniform heating system, the water bath temperature is uniform.
Full-automatic intelligent control of the measurement of time, temperature, and speed, with flexible operation to ensure the accuracy of the measurement.
Real-time display of the actual value and preset value, intuitive display of data to facilitate users to compare data
With automatic operation detection, the operation process can also automatically diagnose whether the fault and alarm function.