English
You are here: Home » Products » Automated External Defibrillator » Automated External Defibrillator ED-5S

loading

Share to:
facebook sharing button
twitter sharing button
whatsapp sharing button
linkedin sharing button
pinterest sharing button
wechat sharing button
line sharing button
sharethis sharing button

Automated External Defibrillator ED-5S

Model : ED-5S

Energy : 200-Joues max
Type : 12V, 2800mAh Li-MnO2 Cell
Size(W×D×H)(mm) : 300x240x80
The ED-5S is a durable, easy-to-use and efficient automated external defibrillator for use in emergency, home and medical station settings.
Availability:
Quantity:

Automated External Defibrillator Features:

1. Data Communications

Automated external defibrillator storage software supports AED to receive data, which is sent through infrared, Scitek AED storage software supports reading and setting of ECG waves, Setting of AED language, Reading, analysis deletion of storage data can be achieved by Scitek AED storage software as well.


2. Case Management

Scitek's Automated external defibrillator storage software makes selected data file as a case record and stores cases by ACCESS database. Case Management supports data importing and data deletion, which can respond to ECG waveform of data file by selecting cases.


3. Memory Playback

The interface display status information recorded in the running of the AED, including type, event time, description, waves. Event type includes on event, self-test event, analyzing event, charging event , discharging event, CPR starting event, CPR stopping event. The event time displayed is when the event happened. Description shows the parameter information. "OHM"represents the detected impedance of the patient. Pxower parameter represents the voltage of the finished charging: "need to shock" represents that shock advised after analyzing "no need to shock" represents that no shock advised after analyzing.


4. ECG

Waveform gain can be set as 5mm/mv, 10mm/mv, 20mm/mv; Waveform speed can be set as 12.5mm/s, 25mm/s, 50mm/s.


5. Print

Print page can preview selected page in the playback interface, which can be used for printing basis information.

Automated External Defibrillator Specifications:

Model ED-5S
Self-test Daily, Weekly, Monthly
Mode Adult, Child
Waveform Biphasic truncated exponential
Energy 200-Joues max.
Energy Sequence Child mode: 50/50/75 Joules
Adult mode: 100/150/200 Joules
Charge Time (New, at 25℃) Less than 6 sec. to 150J
Less than 8 sec. to 200J
Voice Prompt Extensive Voice Prompt
Visual Indicators LED Prompts
Control Two buttons: ON/OFF, Shock
ECG Storage 1500 events
Data Transmission Infrared
Power Supply Battery non-rechargeable
Type 12V, 2800mAh Li-MnO2 Cell
Operating Temperature 0~40℃
Operating Humidity Relative humidity between 30% and 95%(non-condensing)
Storage Temperature
(Without Battery)
-20~55℃
Storage Humidity
(Without Battery)
Up to 93%(non-condensing) Physical
Size(W×D×H)(mm) 300x240x80
Shipping Size(W×D×H)(mm) 320x390x210
N.W./G.W. (kg) 1.9/3.5

Advantage of AED Device:

  1. 2 Languages to choose

  2. 5 Levels of sound volume

  3. Adult / Child Mode Button

  4. Infra-Red for data tra nsmission

  5. Daily, Weekly and Monthly Self-test

  6. Using the AED while in the bag

Automatic External Defibrillator Meter Display

Automated External Defibrillator-1

Meter Display

Automated External Defibrillator-2 Color LED Indicatores for each step
Automated External Defibrillator-3

Energy Sequence Selectable 50 Jto 200] for different age and different situation

Automated External Defibrillator-4

High quality Speaker's design provides great sound and loud which make, it easy to hear the device instructionsin public places

Automated External Defibrillator-5

Visual Steps for Using an Automatic External Defibrillator

Automated External Defibrillator-6

Written Instruction on the device for each step and each button

Automated External Defibrillator-7

Water resistant buttons and soft

How Easy to use

AED Device-1

Start the device

Turn on the power. The voice instruction starts immediately for guide on how to operate AED.

AED Device-2

Attach the pads to the patient

After attaching the pads, AED will immediately start analysing ECG. The device will move to next step only after you attch the pads well.

AED Device-3

Select energy

International resuscitation guideline* recommends to reduce the energy for child patient to avoid burning heart muscle. Meditech ED-5S series can reduce the energy to 30/70J just by select the energy range.

AED Device-4

Press the button

If the shock is needed, the shock button is flashing. Press the button to deliver the electrical shock to the patient.


Previous: 
Next: 
Get Quotation/Become Distributor

About Company​​​​​​​

As a professional lab and medical equipment manufacturer, Scitek Global is certified by ISO 9001, ISO 13485, ISO 45001 and ISO 14001. Almost all our products are certified by ETL, CE and FDA .

Scitek Global looks forward to establishing cooperation with more distributors all over the world, and working together to create greater customer value.

Quick Links

Contact Us
Scitek Global Co.,Ltd
  No. 7000 Jingshi Road, Jinan City, Shandong Province, China
/  +86-531-82893797
  Inquiry: info@scitekglobal.com
Service: 
service@scitekglobal.com
Complaints: 

complaints@scitekglobal.com
 
Scitek Global Inc.
9999 Bellaire Blvd Ste 505, Houston, TX 77036, United States
  +1 (915) 4126735
info@scitekglobal.net
 
Scitek Ethiopia
 tsion@scitekglobal.com
Copyright © 2023 Scitek Global Co., Ltd. All rights reserved.  Sitemap  Privacy Policy